This article describes an issue in which provisioning users to an AuditBoard System for Cross-domain Identity Management (SCIM) fails. The system displays the following error message:
Automatic provisioning of user <user> to app SCIM 2.0 Test App (Header Auth) failed: Error while trying to import user profile for <user>: Error setting property, appUser=<user> property=roles error=[Error in object 'appUser': codes [invalidValueTypeForProperty.appUser,invalidValueTypeForProperty]; arguments [roles]; default message [Invalid value data type]]
- AuditBoard
- System for Cross-domain Identity Management (SCIM)
- Provisioning
- Okta Identity Engine (OIE)
- Okta Classic Engine
The user profile lacks the required attribute, or there is a misconfiguration in the application mappings.
- Access the Okta Admin Dashboard.
- Navigate to Directories and select Profile Editor.
- Select the <app name> application.
- Select Mappings.
- Review the mappings for the roles attribute to ensure correct configuration.
- Confirm the affected user profile contains the required attribute value and matches the expected data type.