This article addresses an error that occurs when pushing attributes from SailPoint to Okta.
[“sailpoint.connector.InvalidRequestException: [ InvalidRequestException ] \n [ Error details ] Request execution failed. HTTP Error code : 400, Okta Error code : E0000001, errorSummary : Api validation failed: newUser, errorCauses:[{errorSummary\u003dProperty name \u0027 is not defined in profile}].“]
- Lifecycle Management
- SailPoint
- Universal Directory
The API validation error occurs because the variable name of the affected attribute in Okta must match the attribute name on the SailPoint side verbatim. This comparison is case sensitive.
To resolve the error, correct the appropriate attribute name on the SailPoint side to match the attribute variable expected by Okta. The specific attribute is detailed in the error message.
NOTE: The attribute value is case sensitive.