<iframe src="https://www.googletagmanager.com/ns.html?id=GTM-M74D8PB" height="0" width="0" style="display:none;visibility:hidden">
Loading
Skip to NavigationSkip to Main Content

Okta Access Gateway Upgrade Fails After Resizing the Terminal Window

Okta Classic Engine
Access Gateway
Okta Identity Engine

Overview

Resizing the terminal window smaller than 80x24 causes an Okta Access Gateway (OAG) upgrade to fail. Resolve this by monitoring the update log from a second terminal and rebooting the node or rolling back to a previous snapshot. Resizing the terminal window smaller than 80x24 during an upgrade causes the terminal to display the following error:

 

Terminal too small (Minimum requirement 80x24). Please resize the terminal.

 

Terminal too small error

 

After resizing the window, the update progress screen displays the following error:

 

Update failed. Review the following and contact Okta support.

 

Update failed error

Applies To

  • Okta Identity Engine (OIE)
  • Okta Classic Engine
  • OAG

Cause

Resizing the terminal window smaller than 80x24 during the upgrade process causes the failure message.

Solution

How is the OAG upgrade failure resolved?

Monitor the update log from a second terminal and reboot the node or roll back to a previous snapshot.

  1. Leave the original terminal window open.
  2. Open a second terminal to the same OAG node and choose 5-System, followed by 0-Launch shell.
  3. Monitor the update log by running the provided command.
sudo tail -f /opt/oag/upgrades/current/yumUpdateOutput.log
  1. Wait until the "Complete!" message appears if the upgrade is still progressing, and then reboot the node to complete the upgrade.
  2. Roll back the node to the backup or snapshot taken before the upgrade and perform the upgrade again if the upgrade does not progress for a few minutes.
Loading